|
Air Vent
Size: 1/2"
-
3/4"
◘ Typical
applications:
☼ Liquid Systems
◘
Main Features:
Any system filled with water or other liquids will not function correctly
unless air and other incondensable gases are removed. EYVAZ Air and Gas
Eliminators prevent air and other gases from retarding circulation, causing
corrosion and noise, inhibiting the filling of systems or priming of pumps.
They are available in a variety of designs for hot water, cold water and
many other liquid systems. EYVAZ Air and Gas Eliminators can easily be
dismantled for servicing, usually without disturbing pipe connections.
◘ Installation:
Cover part can be arranged according to horizontal or vertical
installation type.
◘
Technical Data
| Operating Conditions |
Cast Iron Body |
| Max. Allowable pressure PMA
(bar) |
25 |
| Max. Allowable temperature
TMA
(°C) |
300 |
| Max. Operating pressure PMO
(bar) |
16 |
| Max. Differential pressure
PMD
(bar) |
14 |
| Max. Operating temperature
TMO (°C) |
250 |
| |
| Sizes, Weights & Connections |
Screwed |
Flanged |
| Size (mm) |
½" - ¾" |
15 - 20 |
| Weight (Kg) |
3.2 - 3.2 |
4.5 - 4.8 |
| Connection |
NPT acc. to ANSI BI 20.1 BSP acc. to BS 21 |
DIN 2533 |
|