►Control Valves | Pressure Reducing Valve (Page 2)

Dimensions in mm and weight - Figure (3)

Nominal size   DN

15 20 25 32 40 50 65 80 100

Length L

130 150 160 180 200 230 290 310 350

Length L1
with conical expansion piece

PN 16 220 256 278 314  337 380 464 510 556
PN 25 471 570
Set value Range bar  0.8 ... 2.5 Height H 410 465 595 610
Actuator * D = 225. A = 160 cm2
Operating spring force 4400 N
2 ... 5 Height H 390 445 595 610
Actuator * D = 170. A = 80 cm2  * D = 225. A = 160 cm2
Operating spring force 4400 N 8000N
4.5 ...10 Height H 390 445 575 590
 Actuator * D=170. A=40 cm2  * D = 170. A = 80 cm2
Operating spring force 4400 N 8000 N   7000 N
8 ... 16 Height H 390 445 575 590   
Actuator * D = 170. A = 40 cm2 * D = 225. A = 80 cm2
Operating spring force 8000 N
0.8 ... 2.5 Weight 1) approx.
For PN 16 kg
14 15 15 21 22 26 42 49 58
2 ... 16 12 13 13 18 21 24 40 47 56

Installation
The valve is only suitable for installation in horizontal pipeline. The direction of flow must correspond with the arrow on the body. The valve bonnet, including the actuator, must hong downwards. To keep the valve free of condensate, the pipeline must be installed with a slight fall on either side. the pressure tap should be arranged about I m downstream of the valve.

Because of the increase in volume associated with the reduction in steam pressure, it is often necessary to enlarge the pipeline on the downstream side of the controller. The conical expansion piece shown in the dimensional drawing is suitable for this propose.
 
Kvs - Values - Table 3
DN
Mm
Seat
ø in mm
Kvs
Standard version
15 22 3.2
20 22 5
25 22 8
32 40 12.5
40 40 20
50 40 32
65 65 50
80 65 75
100 65 90

Figure 3

 

Self-operated Pressure Controller Accessories
1. Condensation Chamber
2. Control Line
3. Screw Joint
4. Water Injection Gate
5. Conical Expansion Piece Fig(6)


Fig 4: Pressure controller
with accessories

Application
Accessories for type 39-2. The following accessories are necessary to assure the operation pressure controllers mentioned above.

Condensation Chamber
For steam condensation and for the protection of the operating diaphragm from excessive temperatures.

Screw Joint 3/8" with orifice plate
For the connection of the control line to the actuator of the controller.

Water injection gate
For the filling of the actuator, the condensation chamber, and the control line with a cold liquid corresponding with the controlled medium.

Control Line (3/8" pipe)
For the pressure transmission to the diaphragm of the actuator. The delivery of the control line is not provided.

Conical Expansion piece
To double the outlet diameters in case of steam or gaseous fluids. The delivery of the control line is not provided.

 

 