►Steam Traps | Thermodynamic Steam Trap, Type TD 42 L/H (Page 2)

Optional extras
Insulating Cover: - an insulating cover to prevent the trap being unduly influenced by excessive heat loss such as when subjected low outside temperatures, wind, rain etc.

Installation
Preferably fitted in a horizontal pipe because of the disc balanced but can be fitted in other positions.

Discharge Capacities
 

Recommended Tightening Torques
Item Nm
2(TD42L)
2(TD42H)
36
41
135-150
135-150
5 32     M28 250-275

 
Spare Parts
The spare parts available are shown as below chart:
 
Available Spare Specification No.
Cap (TD42 L or TD42 H) 1
Disc (TD42 L or TD42 H) 2
Strainer Screen (TD42 L or TD42 H) 3
Strainer Cap (TD42 L or TD42 H) 4

How to Service
Remove insulating cover if fitted and unscrew cap using spanner. Do not use stillsons or a wrench of similar type which may cause distortion of the cap.

If the disc and body seating faces are only slightly worn they can be refaced by lapping individually on a flat surface such as a surface plate. A figure of eight motion and a little grinding compound gives the best results. lf the wear is too great to be rectified by simple lapping, the seating faces on the body must be ground flat and then lapped and the disc replaced by a new one. The total amount of metal removed in this way should not exceed 0.25 mm (0.010" ).

When re-assembling the disc is normally placed in position with the grooved side in contact with body seating face. Screw on cap, no gasket is required but a suitable high temperature anti-seize grease should be applied to the threads.

To clean or replace strainer
Unscrew strainer cap using spanner, withdraw screen and clean, or if damaged replace with new one. To re-assemble insert screening cap, then screw cap into place. No gasket is required but a fine smear of molybdenum disulphide grease should be applied to the threads.

 

 