►Steam Traps | Floater Thermostatic Steam Trap - ½", ¾" (Page 1)


Ball Float Steam Trap with Thermostatic
 ΔP: 4.5 - 14 Size:(1/2
" - 3/4")

Typical applications:
Heat exchangers
Heat coil's tanks
Unit heaters
Drying cylinders
Ovens
Pans
Steam lines

Applications:
In the steam lines and related systems the main or a portion of steam will condense due to  heat exchange because to be in contact with environment and transfer of thermal energy. The result of this condensation will be effective strokes in the pipe lines, reducing the system temperature and blocking the steam circulation inside the pipes.

In order to prevent the above cases and to increase the system efficiency and also to transfer the maximum thermal energy and make optimum use of it, the condense should be immediately removed from the system and directed towards condense collection tanks.

This action is done by means of steam trap that keeps the efficiency factor of the steam in a high level. Therefore the presence of steam trap such systems are necessary and condense removal is a necessity. Such steam traps have a thermostat through which the air and excessive gas will be guided out of the system, resulting correct function of the steam trap. If in some cases any problem occurs for the floater, discharge of condensed steam will be done by means of thermostat.

Function and main feature:
A Float through a simply lever mechanism opens or closes the valve according to the condenses level inside the trap. The opening is proportional with condense rate. It is unaffected by instantaneous pressure changing. These types of steam traps specially used where prompts and continues discharge of condense is necessary. For such cases it is very adequate for some Systems such as heat exchangers.

Installation:
The ball float steam traps must be fitted with the float arm in a horizontal plane. In this position the float rises and falls vertically so opens or closes the seat by the valve. It is recognizes by moving the trap to the up and down side by hand. Also the right position of the trap for install indicated with the arrow on the name plate's body. The arrow on the name plate's body in installation place is toward down. Ball float steam trap can be installed in a vertically and horizontally positions. It is possible by remove and return the cover.
Note: Cover part is assembled in vertically position.

Technical Data
Operating Conditions Cast Steel Body Cast Iron Body
Max. Allowable pressure (bar) 40 25
Max. Allowable temperature (°C) 400 300
Max. Operating pressure (bar) 32 16
Max. Operating temperature (°C) 400 250
Max. Differential pressure (∆P) ... 4.5 / ... 10 / ... 14 /
 
Sizes, Weights & Connections Screwed Flanged
Size (Inch) ½" - ¾" ½" -¾"
Weight (Kg) 3.2 - 3.2 3.7 - 3.7
Connection NPT acc. to ANSI DIN 2999 a 20.1 BSP acc. to BS 21 DIN 2533 , ...

 

 